Michele Kearney's Nuclear Wire

Major Energy and Environmental News and Commentary affecting the Nuclear Industry.

Tuesday, April 26, 2011

FEPC Update to Information Sheet Regarding the Tohoku Earthquake 4/26

Update to Information Sheet Regarding the Tohoku Earthquake
For your reference, JAIF (Japan Atomic Industrial Forum) has been posting the translation of news reports on their website. http://www.jaif.or.jp/english/
The Federation of Electric Power Companies of Japan (FEPC) Washington DC Office
As of 11:30AM (EST), April 26, 2011
  • Radiation Levels
    • The concentration of radioactive nuclides from the groundwater sampled at sub-drain pits at Unit 1 to 6 of Fukushima Daiichi Nuclear Power Station were as follows:


Unit 1
Unit 2
Unit 3
Unit 4
Unit 5
Unit 6
Samples taken at
4/25
10:05AM
4/25
10:10AM
4/25
9:55AM
4/25
11:21AM
4/25
10:20AM
4/25
10:24AM
Nuclides
(half-life)
Concentration (Unit : Bq/cm3)
I-131
(8 days)
1.3 x 102
6.1 x 102
2.0 x 101
9.3 x 10-2
1.3 x 10-1
3.8 x 10-1
Cs-134
(2 years)
5.5 x 101
3.3 x 101
3.9 x 100
1.2 x 10-1
2.5 x 10-1
3.3 x 10-1
Cs-137
(30 years)
6.4 x 101
3.7 x 101
4.2 x 100
1.3 x 10-1
3.1 x 10-1
3.9 x 10-1

    • The concentration of radioactive nuclides from the seawater sampled at the screen device (installed to remove waste before the intake of seawater) of Unit 2 and sampled near the seawater discharge point (south side) of Fukushima Daiichi Nuclear Station were as follows:

Nuclides
(half-life)
Concentration (Unit : Bq/cm3)
Ratio
Sampled inside the silt  fence at the screen of Unit 2
Sampled outside the silt fence at the screen of Unit 2
Sampled at south side discharge point
Maximum Permissible Water Concentration (d)
a / d
b / d
c / d
4/25 6:48AM
  (a)
4/25
6:43AM
(b)
4/25 1:40PM
(c)
I-131
(8 days)
5.6 x 101
1.1 x 101
2.1 x 10-2
4.0 x 10-2
1,400
280
0.53
Cs-134
(2 years)
2.6 x 101
3.7 x 100
9.1 x 10-2
6.0 x 10-2
430
62
1.5
Cs-137
(30 years)
2.7 x 101
3.9 x 100
1.0 x 10-1
9.0 x 10-2
300
43
1.1

    • At 3:00PM (JST) on April 26, radiation level at main gate (approximately 3,281 feet from Unit 2 reactor building) of Fukushima Daiichi Nuclear Power Station: 53 micro Sv/hour.
    • At 3:00PM on April 26, radiation level at west gate (approximately 3,609 feet from Unit 2 reactor building) of Fukushima Daiichi Nuclear Power Station: 23.1 micro Sv/hour.
    • Measurement results of environmental radioactivity level around Fukushima Nuclear Power Station announced at 4:00PM on April 26 are shown in the attached PDF file. English version is available at:    http://www.mext.go.jp/english/incident/1304082.htm
    • For comparison, a human receives 2,400 micro Sv per year from natural radiation in the form of sunlight, radon, and other sources. One chest CT scan generates 6,900 micro Sv per scan.

  • Plant Parameters

Unit 1
Unit 2
Unit 3
Unit 4
Unit 5
Unit 6
pressure inside the reactor core (gauge pressure, MPa)
0.445
-0.016
-0.055
-
0.002
0.013
4/26
11:00AM
4/26
11:00AM
4/26
9:00AM
-
4/26
6:00AM
4/26
6:00AM
pressure inside the primary containment vessel (absolute pressure, MPaabs)
0.150
0.080
0.1041
-
-
-
4/26
11:00AM
4/26
11:00AM
4/26
9:00AM
-

...

[Message clipped]  View entire message