Fukushima nuclear accident: Saturday 19 March summary Barry Brook | 20 March 2011 at 12:04 AM | Categories: Hot News, Nuclear | URL: http://wp.me/piCIJ-15h |
Yes, the IAEA has now formally listed the overall accident at an INES level 5 (see here for a description of the scales), up from the original estimate of 4. This is right and proper -- but it doesn't mean the situation has escalated further, as some have inferred. Here is a summary of the main site activities for today, followed by the latest JAIF and FEPC reports. You also might be interested in the following site map:
Another large cohort of 100 Tokyo fire fighters joined the spraying operation to cool down the reactors and keep the water in the spent fuel ponds. They have set up a special vehicle called 'Hyper Rescue' for firing a water cannon from 22 m high (in combination with a super pump truck), and today have been targeting the SNF pond in unit 3. About 60 tons of sea water successfully penetrated the building in the vicinity of the pool, at a flow rate of 3,000 litres per minute. Spraying with standard unmanned vehicles was also undertaken for 7 hours into other parts of the the unit 3 building (delivering more than 1,200 tons), to keep the general containment area cool. The temperature around the fuel rods is now reported by TEPCO (via NHK news) to be below 100C.
Conditions in unit 3 are stabilising but will need attention for many days to come. Promisingly, TEPCO has now connected AC cables to the unit 1 and 2 reactor buildings, with hopes that powered systems can be restored to these building by as early as tomorrow (including, it is hoped, the AC core cooling systems), once various safety and equipment condition checks are made.
Holes were made in the secondary containment buildings of Units 5 and 6 as a precautionary measure, to vent any hydrogen that might accumulate and so prevent explosions in these otherwise undamaged structures. The residual heat removal system for these units has now been brought back on line and these pools maintain a tolerable steady temperature of 60C. More here. These buildings were operating on a single emergency diesel generator, but now have a second electricity supply via the external AC power cable.
Read more of this post
No comments:
Post a Comment